home *** CD-ROM | disk | FTP | other *** search
/ The 640 MEG Shareware Studio 2 / The 640 Meg Shareware Studio CD-ROM Volume II (Data Express)(1993).ISO / utility / pwbg20.zip / PWBG.DOC < prev    next >
Text File  |  1992-12-12  |  11KB  |  295 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10.  
  11.  
  12.  
  13.  
  14.  
  15.  
  16.  
  17.  
  18.                            PW BOOT GUARD 2.0
  19.  
  20.                    Copyright (C) 1992 Lonnie L. Logue
  21.  
  22.  
  23.                    -- THE FLOPPY BOOT PREVENTATIVE --
  24.  
  25.  
  26.  
  27.                                 FEATURES
  28.  
  29.  
  30.         1.  Disables access to the hard drive if the computer was booted
  31.             from a floppy diskette, thereby preventing the bypass of
  32.             config.sys or autoexec.bat password programs.
  33.  
  34.  
  35.  
  36.                               INSTALLATION
  37.  
  38.  
  39.             Syntax: PWBG [switch]
  40.  
  41.             Switch: /i = install
  42.                     /r = remove
  43.  
  44.  
  45.  
  46.                             *** WARNING ***
  47.  
  48.  
  49.         Please run this program only on a bootable floppy disk to
  50.         guarantee complete recovery on non-compatible systems.
  51.  
  52.         After installation, write protect and store the floppy in a safe
  53.         place.  It contains the file PWBG.DAT which is NEEDED to remove
  54.         PWBG 2.0.  Make backup copies of this file and store in a safe
  55.         place.  You can even ZIP them up if you like.
  56.  
  57.  
  58.  
  59.                               COMPATIBLES
  60.  
  61.  
  62.         PW Boot Guard 2.0 has been tested on IBM Compatibles under the
  63.         following conditions:
  64.  
  65.         OPERATING SYSTEMS:  a. MS-DOS 3.3
  66.                             b. MS-DOS 4.01
  67.                             c. MS-DOS 5.0
  68.                             d. DR DOS 6.0
  69.  
  70.  
  71.         NOTE: This product is not compatible with Microsoft Windows
  72.               running in 32 bit disk access mode as Windows modifies the
  73.               Master Boot Record.
  74.  
  75.  
  76.  
  77.                              ERROR MESSAGES
  78.  
  79.  
  80.         1.  REQUIRES DOS VERSION 2.0 OR ABOVE
  81.  
  82.                 DOS version 2.0 or above is required for the operation
  83.                 of this program.
  84.  
  85.  
  86.         2.  PROGRAM MUST BE USED FROM DRIVE A:
  87.  
  88.                 In order to guarantee complete recovery from
  89.                 installations on non-compatible systems, it is necessary
  90.                 for this program to run from a bootable floppy disk in
  91.                 drive A.
  92.  
  93.  
  94.         3.  PW BOOT GUARD ALREADY INSTALLED
  95.  
  96.                 PW Boot Guard is already installed.  Use the /r switch
  97.                 to remove.
  98.  
  99.  
  100.         4.  PW BOOT GUARD NOT INSTALLED
  101.  
  102.                 PW Boot Guard is not installed.  Use the /i switch
  103.                 to install.
  104.  
  105.           NOTE: You may receive this message if PWBG is receiving
  106.                 interference from a software disk cache.  Make sure you
  107.                 boot from a system floppy before attempting removal.
  108.  
  109.                 If PWBG 2.0 has been relocated or damaged by a boot
  110.                 sector virus you may also receive this message.  If you
  111.                 believe this to be the case, boot from the write
  112.                 protected system diskette on which you stored PWBG.DAT
  113.                 and use the hidden /e emergency removal switch by
  114.                 typing: PWBG /e  This will restore your Master Boot
  115.                 Record and Partition Table using the data contained in
  116.                 the PWBG.DAT file.
  117.  
  118.  
  119.         5.  UNABLE TO LOCATE PWBG.DAT
  120.  
  121.                 PW Boot Guard is unable to locate the file PWBG.DAT.
  122.                 Be sure this file, and the program file PWBG.EXE are
  123.                 located on a bootable floppy diskette in drive A: before
  124.                 trying to remove PW Boot Guard.
  125.  
  126.  
  127.         6.  PWBG.DAT SERIAL NUMBER MISMATCH
  128.  
  129.                 The file PWBG.DAT has a different serial number than
  130.                 that assigned during the most recent installation of
  131.                 PWBG 2.0.  It may be that you keep several PWBG.DAT
  132.                 files stored in various places and they just got mixed
  133.                 up.
  134.  
  135.                 The unique serial number safeguards against restoring
  136.                 the PWBG.DAT file of another computer, whose Master Boot
  137.                 Record and Partition Table may be entirely different
  138.                 than yours, onto your computer which may result in the
  139.                 inability to access the hard drive or the loss of data.
  140.                 This may be corrected by restoring immediately with the
  141.                 correct PWBG.DAT file.
  142.  
  143.           NOTE: There is also the chance that the PWBG 2.0 Master Boot
  144.                 Record has been damaged by a virus or other program and
  145.                 no longer contains a correct serial number.  If you
  146.                 believe this to be the case, you may use the hidden /e
  147.                 switch to force emergency removal after first booting
  148.                 from the write protected system diskette on which you
  149.                 stored the PWBG.DAT file.  If you have a boot sector
  150.                 virus, booting from a floppy will make sure that the
  151.                 virus is unable to setup any protection that might
  152.                 prevent it's removal.  It will also disable PWBG 2.0's
  153.                 own write protection mechanism which may also prevent
  154.                 PWBG 2.0 from overwriting the virus.
  155.  
  156.  
  157.         7.  PWBG.DAT IS CORRUPT
  158.  
  159.                 The CRC integrity check on PWBG.DAT has failed.  This
  160.                 file has been corrupted and is unsuitable for use in the
  161.                 removal process.  Use another copy of PWBG.DAT.
  162.  
  163.                 PWBG.DAT is NEEDED for removal of PWBG 2.0, therefore
  164.                 make backup copies of PWBG.DAT and store in a safe
  165.                 place.  You can even ZIP them up if you like.
  166.  
  167.           NOTE: You will also get this message by trying to use versions
  168.                 of PWBG.DAT files prior to 2.0 as they used a different
  169.                 form of error checking.  To view the version of the
  170.                 PWBG.DAT file, at the DOS prompt type: TYPE PWBG.DAT and
  171.                 press Enter.  (A version 2.0 will display PWBG 2.0)
  172.  
  173.  
  174.         8.  FIXED DISK NOT PRESENT OR INVALID
  175.  
  176.                 There is no fixed disk on this system, or it is
  177.                 invalid.
  178.  
  179.  
  180.         9.  INVALID PARTITION TABLE
  181.  
  182.                 PWBG 2.0 will only install onto systems that have a
  183.                 standard 512 byte Master Boot Record which contains a
  184.                 valid, bootable Partition Table.
  185.  
  186.                 If you receive this error message, check to make sure
  187.                 that you don't have a program similar to PWBG 2.0
  188.                 already installed.  Also, boot from a write protected
  189.                 system diskette and scan the C: drive for boot sector
  190.                 viruses using a good virus scanner (i.e. Norton's Anti
  191.                 Virus, SCAN, FPROT etc.) as a virus may have altered the
  192.                 Partition Table, or may have overwritten or relocated
  193.                 PWBG 2.0 if you already had it installed.
  194.  
  195.  
  196.         10.  READ SECTOR FAIL
  197.  
  198.                 PWBG 2.0 encountered a disk sector error while
  199.                 attempting to read the Master Boot Record.  This may be
  200.                 a sign of hard drive trouble.  Boot from a system
  201.                 diskette and try again.  If you have no trouble this
  202.                 time, it may be that a virus or other program is
  203.                 intercepting the sector reads.
  204.  
  205.  
  206.         11.  WRITE SECTOR FAIL
  207.  
  208.                 PWBG 2.0 encountered a disk sector error while
  209.                 attempting to write the Master Boot Record.  This may be
  210.                 a sign of hard drive trouble.  It may also mean that a
  211.                 program (ie. PWMBR or maybe even a virus) has write
  212.                 protected your Master Boot Record.
  213.  
  214.                 If you have the program PWMBR installed, you must first
  215.                 remove it before installing PWBG 2.0.  If you don't have
  216.                 PWMBR installed, boot from a write protected system
  217.                 diskette and scan your hard drive for boot sector
  218.                 viruses.
  219.  
  220.           NOTE: PWMBR is another program I've written.  It is a small
  221.                 and efficient MBR password program which disables floppy
  222.                 diskette boots entirely.
  223.  
  224.  
  225.  
  226.                                 UPDATES
  227.  
  228.  
  229.           1.0 ......... Initial release of this program.
  230.  
  231.           1.1 ......... Bugfix - Found to be non-compatible with SCSI
  232.                         hard drives.  Version 1.0 saved a hidden control
  233.                         file to the root directory of drive C.  The
  234.                         program needed to access this file to remove
  235.                         itself.  When the SCSI hard drive would not boot
  236.                         it became impossible for the user to access the
  237.                         hard drive without reformating or contacting me.
  238.                         Version 1.1 solves this problem nicely by
  239.                         restricting it's operation to drive A.  It saves
  240.                         a non-hidden encrypted control file.  This file
  241.                         is needed for removal, please make backups and
  242.                         store in a safe place.
  243.  
  244.           1.2 ......... Bugfix - If the disk in drive A were full
  245.                         (unlikely, but possible), the program would
  246.                         continue installation even though the control
  247.                         file was not properly saved.  This version
  248.                         corrects the problem.  Tightened code, modified
  249.                         control file signature to prevent the reading of
  250.                         previous versions control files.
  251.  
  252.           2.0 ......... Now compatible with SCSI drives as Partition
  253.                         Table is no longer scrambled.  Norton's Disk
  254.                         Doctor will no longer recognize a defect in the
  255.                         Partition Table.  Added a /e trapdoor switch so
  256.                         that PWBG 2.0 will use any valid version 2.0 or
  257.                         higher PWBG.DAT file to restore the Master Boot
  258.                         Record and Partition Table even if the PWBG.DAT
  259.                         serial number doesn't match as might be the case
  260.                         if the Master Boot Record has been damaged by a
  261.                         virus or other program.
  262.  
  263.  
  264.                             SOFTWARE LICENSE
  265.  
  266.  
  267.                    Copyright (C) 1992 Lonnie L. Logue
  268.  
  269.  
  270.         This product is SHAREWARE!  You may use PWBG.EXE without charge
  271.         for an evaluation period not to exceed 30 days.  Continued use
  272.         after the evaluation period requires registration.  Use of this
  273.         software, registered or not, is NOT permitted unless the following
  274.         conditions are agreed to:
  275.  
  276.             1.  No fee is charged for use, copying or distribution.
  277.  
  278.             2.  It is not modified in any way.
  279.  
  280.         If you find this program useful, a $5 registration would be
  281.         appreciated.  Please send CASH, check or money order to:
  282.  
  283.                             Lonnie L. Logue
  284.                             9231 Goldenrod Lane
  285.                             Upper Marlboro, MD  20772
  286.  
  287.  
  288.  
  289.  
  290.  
  291.  
  292.  
  293.                                  -EOF-
  294.  
  295.